1. Standard Type
Inlet Water Temperature: t1=37 ℃
Outlet Water Temperature: t2=32 ℃
Wet-bulb Temperature: WBT=28 ℃
Dry-bulb Temperature: θ= 31.8 ℃
Atmospheric Pressure: P=9.94 × 10104Pa
2. Industrial Type
Inlet Water Temperature:12=43℃
Outlet Water Temperature:t2=33℃
Wet-bulb Temperature:WBT=28℃
Dry-bulb Temperature:6=31.8℃
Atmospheric Pressure:P=9.94×10104Pa
3. Water Turbidity
The turbidity of the circulating water in the cooling tower generally does not exceed 50mg/L, and is allowed to not exceed 100mg/L in the short term.
CLF series standard type, low noise type (- L) parameter table:
Model/ Parameter | Cooling Water Volume | Dynamical System | Overall Dimensions | Tower Head | ||||
Fan Diameter | Power | Air Volume | Length | Width | Height | |||
L | W | H | ||||||
m³/h | φmm | Kw | m³/h | mm | mm | mm | mh₂O | |
CLF-75L | 75 | 1470 | 3 | 47000 | 2400 | 2400 | 4470 | 3 |
CLF-100L | 100 | 1800 | 4 | 59000 | 2800 | 2800 | 4720 | 3.1 |
CLF-125L | 125 | 2000 | 4 | 88000 | 2800 | 2800 | 4720 | 3.1 |
CLF-150L | 150 | 2000 | 5.5 | 100000 | 3200 | 3200 | 4760 | 3.3 |
CLF-175L | 175 | 2400 | 5.5 | 117000 | 3200 | 3200 | 4760 | 3.3 |
CLF-200L | 200 | 2400 | 7.5 | 132000 | 3600 | 3600 | 4900 | 3.4 |
CLF-250L | 250 | 3000 | 7.5 | 176000 | 4000 | 4000 | 5220 | 3.4 |
CLF-300L | 300 | 3000 | 11 | 193000 | 4400 | 4400 | 5640 | 3.4 |
CLF-400L | 400 | 3400 | 11 | 234000 | 5000 | 5000 | 5740 | 3.6 |
CLF-500L | 500 | 3700 | 15 | 293000 | 5600 | 5600 | 6130 | 3.6 |
CLF-600L | 600 | 4200 | 18.5 | 352000 | 6200 | 6200 | 6150 | 3.7 |
CLF series industrial type (- L) parameter table:
Model/ Parameter | Cooling Water Volume | Dynamical System | Overall Dimensions | Tower Head | ||||
Fan Diameter | Power | Air Volume | Length | Width | Height | |||
L | W | H | ||||||
m³/h | φmm | Kw | m³/h | mm | mm | mm | mh₂O | |
CLF-100L | 100 | 2000 | 5.5 | 100000 | 3200 | 3200 | 5260 | 3.1 |
CLF-125L | 125 | 2400 | 5.5 | 117000 | 3200 | 3200 | 5260 | 3.1 |
CLF-150L | 150 | 2400 | 7.5 | 132000 | 3600 | 3600 | 5400 | 3.2 |
CLF-175L | 175 | 2700 | 7.5 | 147000 | 3600 | 3600 | 5400 | 3.2 |
CLF-200L | 200 | 3000 | 11 | 176000 | 4000 | 4000 | 5720 | 3.4 |
CLF-250L | 250 | 3000 | 11 | 193000 | 4400 | 4400 | 6140 | 3.5 |
CLF-300L | 300 | 3400 | 15 | 234000 | 5000 | 5000 | 6240 | 3.5 |
CLF-400L | 400 | 3700 | 18.5 | 293000 | 5600 | 5600 | 6630 | 3.5 |
CLF-500L | 500 | 4200 | 22 | 352000 | 6200 | 6200 | 6650 | 3.7 |
CLF-600L | 600 | 4200 | 30 | 410000 | 6900 | 6900 | 7120 | 3.7 |
Basic Dimension Drawing I
Model/ Parameter | L | L1 | L2 | L3 |
mm | mm | mm | mm | |
CLF-75L | 2400 | 800 | 800 | 1200 |
CLF-100L~CLF-125L | 2800 | 900 | 1000 | 1400 |
CLF-150L~CLF-175L CLF-100L~CLF-125L | 3200 | 1000 | 1200 | 1600 |
CLF-200L CLF-150L~CLF-175L | 3600 | 1200 | 1200 | 1800 |
CLF-250L CLF-200L | 4000 | 1300 | 1400 | 2000 |
CLF-300L CLF-250L | 4400 | 1400 | 1600 | 2200 |
Basic Dimension Drawing II
Model/ Parameter | L | L1 | L2 | L3 |
mm | mm | mm | mm | |
CLF-400L CLF-300L | 5000 | 1600 | 1800 | 2500 |
CLF-500L CLF-400L | 5600 | 1800 | 2000 | 2800 |
CLF-600L CLF-500L | 6200 | 2000 | 2200 | 3100 |
CLF-600L | 6900 | 2300 | 2300 | 3450 |
TIANMA, a leading FRP Cooling Tower supplier, specializes in providing cutting-edge solutions for efficient heat dissipation in industrial processes. Our FRP Cooling Tower stands out for its advanced design and superior performance in various applications.
The hallmark of our cooling tower is the innovative "cooling tower frp structure," which ensures durability, corrosion resistance, and optimal heat exchange efficiency. The FRP structure in our cooling towers is engineered to withstand harsh environmental conditions, making it an ideal choice for industries where cooling is critical.
At TIANMA, we understand that cost is a crucial factor for our clients. Therefore, we offer competitive pricing, and our commitment to quality ensures that the "frp cooling tower price" aligns with the exceptional value our product provides. We believe in delivering cost-effective solutions without compromising on performance.
The integration of FRP in cooling tower technology has revolutionized the industry, and our products exemplify this innovation. The "frp in cooling tower" feature enhances the tower's resistance to corrosion, chemicals, and extreme temperatures, making it a reliable choice for diverse industrial applications.
TIANMA takes pride in offering a range of cooling solutions, with our flagship product being the "frp structure cooling tower." This design not only ensures structural integrity but also facilitates efficient heat dissipation, contributing to the overall productivity of industrial processes.
Our commitment to excellence is further demonstrated through the versatility of the "frp type cooling tower" we provide. Whether in power plants, manufacturing facilities, or chemical processing units, our FRP Cooling Tower stands as a testament to reliable and sustainable cooling solutions.
In conclusion, TIANMA's FRP Cooling Tower is a top-tier choice for industries seeking state-of-the-art cooling solutions. The emphasis on "cooling tower frp structure," "frp cooling tower price," and "frp in cooling tower" underscores our dedication to delivering high-quality products that exceed customer expectations. Experience the difference with TIANMA's FRP Cooling Tower – where innovation meets efficiency.
Tianma Group Corp is engaged in research on fiberglass/composite material products and related technologies, and has won multiple national, provincial, and municipal level scientific and technological progress awards. Based on this, the company implements a technological innovation strategy, actively cooperates with domestic and foreign research institutes, targets and tracks international market trends, continuously develops new products with independent intellectual property rights, and enhances core competitiveness.
E-mail: sales1@tm253.com
Tel: 0086-519-68193652
Add: No. 309 Huanghai Rd, Xinbei District, Changzhou, Jiangsu, China